<h2> Employing the Balanset-1A System </h2>
<h3> Getting the Equipment Ready </h3>
<ul>
<li> vibration sensors, optical speed sensor, magnetic base, software package, and included accessories. </li>
<li> Establish a USB connection between the instrument and the computer, ensuring the software is set up properly. </li>
</ul>
<h3> Mounting the Sensors </h3>
<ul>
<li> Mount the vibration transducers securely on the machine's housing where vibrations are most pronounced, typically near the bearings. </li>
<li> Position the laser tachometer (phase angle sensor) so that it is aimed at the rotor. Attach reflective tape to the rotor for accurate phase angle reading. </li>
</ul>
<h3> Software Startup </h3>
<ul>
<li> Open the Balanset application on your PC. </li>
<li> Choose the correct balancing method (single or two-plane) according to the rotor configuration and the balancing task. </li>
</ul>
<h3> Measuring Initial Vibration </h3>
<a href="https://vibromera.eu/wp-content/uploads/2024/11/2-Camera_01.png" target="_blank">
<img src="https://vibromera.eu/wp-content/uploads/2024/11/2-Camera_01.png" alt="2-Camera_01" style="width: 50%; display: block; margin-bottom: 10px;">
</a>
<ul>
<li> Run the rotor up to its operating speed. </li>
<li> The application will acquire data on vibration magnitude, rotational velocity, and phase angle to determine the initial imbalance state. </li>
</ul>
<h3> Trial Weight Installation </h3>
<a href="https://vibromera.eu/wp-content/uploads/2024/11/3-Camera-2_01.png" target="_blank">
<img src="https://vibromera.eu/wp-content/uploads/2024/11/3-Camera-2_01.png" alt="3-Camera-2_01" style="width: 50%; display: block; margin-bottom: 10px;">
</a>
<ul>
<li> Halt the rotation and mount a test weight at a designated position on the rotor, with the weight's value entered into the software (usually in grams). </li>
<li> Run the rotor again, allowing the software to measure the effects of the trial weight on vibration and phase. </li>
</ul>
<a href="https://vibromera.eu/wp-content/uploads/2024/11/5-Camera_01.png" target="_blank">
<img src="https://vibromera.eu/wp-content/uploads/2024/11/5-Camera_01.png" alt="5-Camera_01" style="width: 50%; display: block; margin-bottom: 10px;">
</a>
<h3> Computing the Compensating Weight </h3>
<ul>
<li> The software uses the measured values to automatically compute the necessary compensating weight's magnitude and placement angle. </li>
<li> The calculated values are presented on-screen in both numerical and graphical formats. </li>
</ul>
<a href="https://vibromera.eu/wp-content/uploads/2024/02/Bs1ManualEngV156-May2023-10448629.png" target="_blank">
<img src="https://vibromera.eu/wp-content/uploads/2024/02/Bs1ManualEngV156-May2023-10448629.png" alt="Bs1 Manual" style="width: 30%; display: block; margin-bottom: 10px;">
</a>
<h3> Mounting the Compensating Weight </h3>
<ul>
<li> Install the correction weight on the rotor according to the software's calculations. </li>
<li> Periodic checks can be performed to ensure the balancing procedure is effectively reducing the vibration. </li>
</ul>
<a href="https://vibromera.eu/wp-content/uploads/2024/11/1-Camera-2_01.png" target="_blank">
<img src="https://vibromera.eu/wp-content/uploads/2024/11/1-Camera-2_01.png" alt="1-Camera-2_01" style="width: 50%; display: block; margin-bottom: 10px;">
</a>
<h3> Verification and Balancing Completion </h3>
<ul>
<li> Once the corrective weight is in place, restart the rotor and measure the remaining vibration amplitude. </li>
<li> The balancing procedure is finished if the remaining vibration is within the permissible limits specified in ISO 1940. </li>
<li> Should the vibration still be excessive, repeat the balancing steps, making further adjustments to the corrective weight as needed. </li>
</ul>
<h3> Report Generation </h3>
<ul>
<li> The program stores the balancing data, allowing you to generate and print a comprehensive report including vibration measurements, corrective weight details, and its angular placement. </li>
</ul>
<h3> Final Recommendations </h3>
<ul>
<li> Ensure all applied weights and attached sensors are firmly fixed in their designated positions. </li>
<li> Ensure the rotor rotates smoothly and without excessive noise. </li>
<li> If the rotor operates within a larger assembly, check the functionality and interplay of all interconnected parts. </li>
</ul>
<p> </p>
Instagram: https://www.instagram.com/vibromera_ou/
Youtube : https://youtu.be/guA6XJ-ArZM?si=vmkuX7RILzKBl0zL
Our website about <a href="https://vibromera.eu
"> Balancing adapter </a>
Machinio: https://www.machinio.com/listings/98380186-portable-balancer-vibration-analyzer-balanset-1a-full-kit-in-portugal
Facebook: https://www.facebook.com/marketplace/item/350151228150722
http://skvortsy.listbb.ru/viewtopic.php?f=31&t=2619